Tata Voltas AC Error Code List
Voltas air conditioners typically use error codes to indicate issues with the unit. The error codes can vary depending on the model and make of the air conditioner.
As a consumer, you have several questions. You often see a Voltas AC error code in India on the air conditioning unit. Voltas air conditioner error code has been the most searched topic in recent times. We understand your concern, so we bring you what each error code means.
List Voltas AC Error Code
Voltas AC Error Code EE | The error code shows when you have an issue with Voltas indoor machine. |
Voltas AC Error Code E0 | The error code shows when there is an issue with the outdoor machine EE. |
Voltas AC Error Code E1 | The error code shows when you have an issue with the indoor fan. |
Voltas AC Error Code E2 | The error code shows when you have an issue with zero-crossing detection indoor fan. |
Voltas AC Error Code E3 | The error code shows when you have an issue with the sensor and indoor coil fault. You might need coil overheat protection. |
Voltas AC Error Code E4 | The error code shows when there is an issue with your Voltas indoor ambient temperature sensor. |
Voltas AC Error Code E5 | The error code shows when there is a problem with the fan operation. |
Voltas AC Error Code E6 | The error code shows when there is an outdoor and indoor machine communication issue. |
Voltas AC Error Code E8 | The error code shows when there is a problem with outdoor communication. |
Voltas AC Error Code F1 | The error code shows when you have a problem with the compressor starting up. |
Voltas AC Error Code F2 | The error code shows when you have a problem with your compressor. |
Voltas AC Error Code F3 | The error code shows when you have a problem with the IPM module. |
Voltas AC Error Code F4 | The error code shows when you have a problem with the compressor shell roof. |
Voltas AC Error Code F5 | The error code shows when you have a problem with the discharge temperature sensor. |
Voltas AC Error Code F6 | The error code shows when you have a problem with the section temperature sensor. |
Voltas AC Error Code F7 | The error shows when you have a problem with the coil temperature sensor or there is a temperature sensor fault. |
Voltas AC Error Code F8 | The error code shows when you have a problem with the ambient temperature sensor. |
Voltas AC Error Code F9 | The error code shows when you have a problem with your outdoor DC fan. |
Voltas AC Error Code P1 | The error code shows when you have a problem with the machine air conditioning current protection. |
Voltas AC Error Code P2 | The error code shows when you have an issue with the compressor phase current protection. |
Voltas AC Error Code P3 | The error code shows when you have a problem with your outdoor unit air conditioner/ac voltage protection. |
Voltas AC Error Code P4 | The error code shows when you have a problem with the DC voltage protection. |
Voltas AC Error Code P5 | The error code shows when you have a problem with IPM over-high temperature protection. |
Voltas AC Error Code P6 | The error code shows when you have a problem with the discharge temperature overheat protection. |
Voltas AC Error Code P7 | The error code shows when you have a problem with the cooling coil anti-freezing protection. |
Voltas AC Error Code L4 | The error code shows when you have a problem with the phase current samping. |
Voltas AC Error Code U1 | The error code shows when there is a problem with the IPM overcurrent protection. |
Voltas AC Error Code U3 | The error code shows when you have a problem with the compressor overcurrent protection. |
Voltas AC Error Code U4 | The error code shows when you have a problem with over voltage protection. |
Voltas AC Error Code U5 | The error code shows when you have a problem with low-voltage protection. |
Voltas AC Error Code U7 | The error code shows when you have a problem with over-speed protection. |
Voltas AC Error Code 1E | Issue with outdoor unit room temperature sensor. |
Voltas AC Error Code 2E | Issue with unit pipe temperature sensor (outdoor unit). |
Voltas AC Error Code 3E | Issue with exhaust sensor. |
Voltas AC Error Code 4E | Module board needs to be replaced. |
Voltas AC Error Code 8E | Issue with PFC. Need to replace the module board. |
Voltas AC Error Code H1 | Automatic defrosting |
Voltas AC Error Code H3 | Halt for compressor overload protection. |
Voltas AC Error Code H4 | Overload protection |
Voltas AC Error Code PL | protection against low voltage |
Voltas AC Error Code C5 | Jumper cap malfunction |
Voltas AC Installation Code List
- E1, E2, F7, F1 – Indoor room sensor fault
- E4, F6, H6, E5 – Indoor blower motor fault
- E6, E5 – Over current protection
- E0, 1-time blink – Indoor unit EEPROM parameter fault
- E1, 2-time blink – Indoor – Outdoor communication fault
- E2, 3-time blink – Zero current crossing fault
- E3, 4-time blink – Indoor fan speed out of control
- E4, 5-time blink – Indoor temperature sensor fault
- E5, 6-time blink – Indoor coil sensor fault
- EC, 7-time blink – Refrigerant leak
- F0, 1-time blink – Overload Current Protection
- F1, 2-time blink – Outdoor temperature sensor fault
- F2, 3-time blink – Outdoor condenser sensor fault
- F3, 4-time blink – Discharge pipe sensor fault
- F4, 5-time blink – Outdoor EEPROM parameter fault
- P1, 2-time blink – Over and low voltage fault
- Filter Cleaning
Voltas AC Unlock Code List
S.No | Code on Display | Password |
---|---|---|
1 | 00 | 1234B |
2 | 01 | 98A43 |
3 | 02 | 8A493 |
4 | 03 | 34A89 |
5 | 04 | A8349 |
6 | 05 | 349A8 |
7 | 06 | 83A49 |
8 | 07 | 48A48 |
9 | 08 | 4983A |
10 | 09 | A3498 |
11 | 0A | A8349 |
12 | 0C | 985B6 |
13 | 0D | 6B589 |
14 | 0E | B5896 |
15 | 0F | 5896B |
16 | 10 | 8965B |
17 | 11 | B5689 |
18 | 12 | B6985 |
19 | 13 | 69B85 |
20 | 14 | 685B9 |
21 | 15 | 658B9 |
22 | 16 | 6985B |
23 | 17 | 123D4 |
24 | 18 | 321D4 |
25 | 19 | 231D4 |